LeCroy LW4-508040 The is the PCI-based member of GE Fanuc Embedded Systems' family of Reflective Memory real time fiber-optic network products. Two or more s and other members of this family can be integrated into a network using standard fiber-optic cables. Each board in the network is referred to as a node. Reflective Memory allows computers, workstations, PLCs and other embedded controllers with different architectures and dissimilar operating systems to share data in real time. The VMIxxx-5565 family of Reflective Memory is fast, flexible and easy to operate. Data is transferred by writing to memory (SDRAM), which appears to reside globally in all boards on the network. Onboard circuitry automatically performs the transfer to all other nodes with little or no involvement of any host processor or system. A block diagram of the is shown in Figure 1 on page 15. Features • High speed, easy to use fiber-optic network (2.12 Gbaud serially) • PCI 64-bit 66MHz transfers • No host processor involvement in the operation of the network • Redundant Mode of Operation • Up to 256 nodes • Connectivity with multimode fiber up to 300 meters • Dynamic packet size, 4 to 64 bytes of data per packet • Transfer rate 47.1MB/s (4 byte packet) to 174 MB/s (64 byte packet) • 64MB or 128MB SDRAM Reflective Memory with parity • Two independent Direct Memory (DMA) channels • Configurable endian conversion for multiple CPU architectures on the same network Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com Ultrahigh Speed Fiber-Optic Reflective Memory with Interrupts 14 PCI Local Bus Compliance The complies with requirements of the PCI Local Bus Specification, version 2.2. Vendor and Device Identification The PCI Configuration register reserved for the vendor ID has the value of $114A, which designates GE Fanuc Embedded Systems. The PCI Configuration register reserved for the device ID has the value of $5565, which is GE Fanuc Embedded Systems' board type. Subsystem Vendor ID and Subsystem ID The PCI Configuration register reserved for the subsystem vendor ID has the value of $10B5, which designates PLX Technology. The PCI Configuration register reserved for the subsystem ID has the value of $9656, which is the PLX device part number. Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com Overview 15 Figure 1 Block Diagram SDRAM Memory 128 Mbytes 256 Mb x 8-bit x 5 chips OR 64 Mbytes 128 Mb x 8-bit x 5 chips PCI Interface 66 MHz/32-bit Multiplexed Addr/Data Handshake Data Address 11 bits Control Read Empty 66 MHz x36 bits RX FIFO 4 k x 36-bit Main FPGA (66 MHz) Write Almost Full 66 MHz x36 bits PRBSEN LOOPEN ENDEC/ SERDES RX_ER RX_DV 106 MHz x36 bits Write Almost Empty RX FPGA (106 MHz) 106 MHz 16 bits TX_EN TX_ER 106 MHz 16 bits TX FPGA (106 MHz) 106 MHz Read x36 bits Empty TX FIFO 4 k x 36-bit PECL 2.12 Gb 10-bit PECL 2.12 Gb 10-bit TRANSCEIVER RX TX Fiber-Optic Network 66 MHz 64-bit PCI bus Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com Ultrahigh Speed Fiber-Optic Reflective Memory with Interrupts 16 Figure 2 Typical Reflective Memory Network NODE 2 VMEbus Computer Nodes can be VMEbus-Based Computers or Computers with VMEbus I/O Channels Such as Harris Nighthawk, Concurrent, Silicon Graphics, Data General, Motorola Delta Series, Encore 91 series or any VMEbus Chassis 5 5 6 5 PCI WorkStation with NODE 1 VMEbus Chassis with VMIPMC-5565 NODE 255 VMIPMC-5565 Up to 300 m between nodes VMEbus Chassis with VMIVME-5565 NODE 0 VMIV 55 ME 65 VMIVME-5565 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com Overview 17 Organization of the Manual This manual is composed of the following chapters: Overview - provides an introduction of the , Organization of the manual, References, Safety summary and Saftey symbols. Chapter 1 - Theory of Operation describes the functionality of the Reflective Memory board and provides descriptions of the major sub-circuits and their operation. Chapter 2 - Configuration and Installation describes unpacking, inspection, hardware jumper settings, connector definitions, installation, cable configuration and board layout. Chapter 3 - Programming describes registers like PCI Configuration, Local Configuration, Runtime, DMA Control, RFM Control and Status Registers. Maintenance - provides information relative to the care and maintenance of the unit. Compliance - provides the applicable information regarding regulatory compliance for the . Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com Ultrahigh Speed Fiber-Optic Reflective Memory with Interrupts 18 References GE Fanuc Embedded Systems’ Physical Description and Specifications Doc. No. 800-855565-000 GE Fanuc Embedded Systems 12090 South Memorial Pkwy. Huntsville, AL 35803-3308 (800) 322-3616 www.gefanucembedded.com Refer to PCI Local Bus Specification for a detailed explanation of the PCI Local bus. The PCI Local bus Specification is available from the following source: PCI Special Interest Group P.O. Box 14070 Portland, OR 97214 U.S.: (800) 433-5177 International: (503) 797-4207 FAX: (503) 234-6762 For a detailed explanation of the PCI-9656 I/O Accelerator, refer to PLX PCI-9656 Data Book Revision 0.90 from: PLX Technology Inc. 870 Maude Av. Sunnyvale, CA 94085 U.S.: (408) 774-9060 (800) 759-3735 FAX: (408) 774-2169 www.plxtech.com E-mail: 9656@plxtech.com Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com Overview 19 Safety Summary The following general safety precautions must be observed during all phases of the operation, service and repair of this product. Failure to comply with these precautions or with specific warnings elsewhere in this manual violates safety standards of design, manufacture and intended use of this product. GE Fanuc Embedded Systems assumes no liability for the customer's failure to comply with these requirements. Ground the System To minimize shock hazard, the chassis and system cabinet must be connected to an electrical ground. A three-conductor AC power cable should be used. The power cable must either be plugged into an approved three-contact electrical outlet or used with a three-contact to two-contact adapter with the grounding wire (green) firmly connected to an electrical ground (safety ground) at the power outlet. Do Not Operate in an Explosive Atmosphere Do not operate the system in the presence of flammable gases or fumes. Operation of any electrical system in such an environment constitutes a definite safety hazard. Keep Away from Live Circuits Operating personnel must not remove product covers. Component replacement and internal adjustments must be made by qualified maintenance personnel. Do not replace components with power cable connected. Under certain conditions, dangerous voltages may exist even with the power cable removed. To avoid injuries, always disconnect power and discharge circuits before touching them. Do Not Service or Adjust Alone Do not attempt internal service or adjustment unless another person capable of rendering first aid and resuscitation is present. Do Not Substitute Parts or Modify System Because of the danger of introducing additional hazards, do not install substitute parts or perform any unauthorized modification to the product. Return the product to GE Fanuc Embedded Systems for service and repair to ensure that safety features are maintained. Dangerous Procedure Warnings Warnings, such as the example below, precede only potentially dangerous procedures throughout this manual. Instructions contained in the warnings must be followed. WARNING: Dangerous voltages, capable of causing death, are present in this system. Use extreme caution when handling, testing and adjusting. Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com Ultrahigh Speed Fiber-Optic Reflective Memory with Interrupts 20 Safety Symbols Used in This Manual STOP: Informs the operator that a practice or procedure should not be performed. Actions could result in injury or death to personnel, or could result in damage to or destruction of part or all of the system. WARNING: Denotes a hazard. It calls attention to a procedure, a practice, a condition, which, if not correctly performed or adhered to, could result in injury or death to personnel. CAUTION: Denotes a hazard. It calls attention to an operating procedure, a practice, or a condition, which, if not correctly performed or adhered to, could result in damage to or destruction of part or all of the system. NOTE: Denotes important information. It calls attention to a procedure, a practice, a condition or the like, which is essential to highlight. |