欢迎访问瑞昌明盛自动化设备有限公司官网!
关于我们 | 联系我们

+86 15270269218

您的位置:首页>>产品中心 >> foxboro

GE IS210BPPBH2BMD模块备件

型号: GE IS210BPPBH2BMD  分类: foxboro
  • GE IS210BPPBH2BMD
  • GE IS210BPPBH2BMD
  • GE IS210BPPBH2BMD
  • GE IS210BPPBH2BMD
  • GE IS210BPPBH2BMD


GE IS210AEBIH3BEC

in the AUTO mode, the feedback
signal must be connected to analogue input 2 (AI2) and the
START command is given with digital input 1 (DI1). By default,
the setpoint is set from the control panel (operator keypad), but it
can also be given through the analogue input 1. Process PI(D)
must be commissioned and adjusted with parameters (Group
40: PROCESS PID SET 1) or using the PID control assistant
(recommended).
© Copyright 2007 ABB
ACH550-01 User's Manual
Application macros and wiring 109
1 SCR Signal cable shield (screen)
2 AI1 External reference 1: 0(2)…10 V or 0(4)…20 mA
3 AGND Analogue input circuit common
4 10V Reference voltage +10 V DC
5 AI2 Actual signal 1: 0(2)…10 V or 0(4)…20 mA 2
6 AGND Analogue input circuit common
7 AO1 Output frequency: 0(4)…20 mA
8 AO2 Output current: 0(4)…20 mA
9 AGND Analogue output circuit common
10 24V Auxiliary voltage output +24 V DC
11 GND Common for DI return signals
12 DCOM Digital input common for all
13 DI1 Start/Stop: Activation starts the drive
14 DI2 Run enable: Deactivation stops the drive 1
15 DI3 Not used
16 DI4 Interlock: Deactivation stops the drive
17 DI5 Interlock: Deactivation stops the motor
18 DI6 Not used
19 RO1C Relay output 1 (par. 1401)
Default operation
Aux. motor switched on => 19 connected to 21
20 RO1A
21 RO1B
22 RO2C Relay output 2 (par. 1402)
Default operation
Running => 22 connected to 24
23 RO2A
24 RO2B
25 RO3C Relay output 3 (par. 1403)
Default operation
Fault (-1) => 25 connected to 27
26 RO3A
27 RO3B
1 Disable/enable with parameter 1601 2 The sensor for AI2 is powered externally (not shown in the figure). See the manufacturer’s
instructions. To use sensors supplied by the drive auxiliary voltage output, see page 124.
Note: The drive starts only if possible protection functions (Run enable or Start enable 1 and
2) are activated from I/O or disabled with parameters.
1…10 kohm
Pump alternation
ACH550-01 User's Manual
110 Application macros and wiring
8. Internal timer
This application macro is for applications where the motor is
started and stopped with a built-in timer. This macro has also a
boost function which operates the motor after digital input 3
(DI3) has been momentarily activated. An example of the timer
usage is shown below. For further information see chapter Realtime clock and timed functions.
When using a direct speed reference in the AUTO mode, the
speed reference must be connected to analogue input 1 (AI1)
and the START command is given with digital input 1 (DI1). In
the HAND/OFF mode, the speed reference and START
command are given through the control panel (operator keypad).
If process PI(D) is used, the feedback signal must be connected
to analogue input 2 (AI2). By default, the setpoint is set from the
control panel, but it can also be changed to analogue input 1.
Process PI(D) must be commissioned and adjusted with
parameters (Group 40: PROCESS PID SET 1) or using the PID
control assistant (recomm

GE IS210AEBIH3BEC

GE IS210BPPBH2BMD模块备件

GE IS210AEBIH3BEC

在自动模式下
信号必须连接到模拟输入2(AI2)和
用数字输入1(DI1)给出启动命令。默认情况下,
设定点是从控制面板(操作员键盘)设置的,但是
也可以通过模拟输入1给出。过程PI(D)
必须使用参数(组)进行调试和调整
40:过程PID设置1)或使用PID控制助手
(推荐)。
©版权所有2007 ABB
ACH550-01用户手册
应用程序宏和布线109
1个SCR信号电缆屏蔽(屏幕)
2 AI1外部参考1:0(2)…10 V或0(4)…20 mA
3 AGND模拟输入电路公共
4 10V参考电压+10V直流电
5 AI2实际信号1:0(2)…10 V或0(4)…20 mA 2
6 AGND模拟输入电路公共
7 AO1输出频率:0(4)…20mA
8 AO2输出电流:0(4)…20mA
9 AGND模拟输出电路公共
10 24V辅助电压输出+24 V直流电
11 DI返回信号的接地公共线
12 DCOM数字输入通用于所有
13 DI1启动/停止:激活启动驱动器
14 DI2运行启用:停用将停止驱动器1
15不使用DI3
16 DI4联锁:停用会停止驱动
17 DI5联锁:停用会停止电机
18未使用DI6
19 RO1C继电器输出1(1401段)
默认操作
辅助的。电机打开=>19连接到21
20 RO1A
21 RO1B
22 RO2C继电器输出2(1402段)
默认操作
运行=>22连接到24
23 RO2A
24 RO2B
25 RO3C继电器输出3(1403段)
默认操作
故障(-1)=>25连接到27
26 RO3A
27 RO3B
1禁用/启用参数1601 2 AI2的传感器由外部供电(图中未显示)。请参阅制造商的
说明书要使用由驱动辅助电压输出提供的传感器,请参阅124页。
注意:只有在可能的保护功能(运行启用或启动启用1和2)下,驱动器才会启动
2) 通过I/O激活或通过参数禁用。
1…10千欧
泵交替
ACH550-01用户手册
110应用程序宏和布线
8.内部定时器
此应用程序宏适用于电机运行的应用程序
使用内置定时器启动和停止。此宏还有一个
升压功能,在数字输入3后操作电机
(DI3)已被瞬时激活。定时器的示例
用法如下所示。有关更多信息,请参阅“实时时钟和定时功能”一章。
在自动模式下使用直接速度参考时
速度基准必须连接到模拟输入1(AI1)
并且用数字输入1(DI1)给出启动命令。在里面
切换/断开模式、速度参考和起动
通过控制面板(操作员键盘)发出命令。
如果使用过程PI(D),则必须连接反馈信号
至模拟输入2(AI2)。默认情况下,设定点是从
控制面板,但也可以更改为模拟输入1。
工艺PI(D)必须通过以下方式进行调试和调整:
参数(组40:过程PID设置1)或使用PID
控制助理(RECOM)



更多
查看更多 >>

推荐产品