KJ3243X1-BA1
I/O卡、I/O卡键控、传统I/O终端块、大规模终端块
AI,8通道,4-20 mA,HART A1输入/输出端子板
带保险丝的输入/输出端子块
4线I/O接线板
16引脚质量接线板
(支持双线设备)
24引脚质量接线板
(支持4线设备)
AI Plus,16通道,4-20 mA,HART A6 16通道双线AI
系列2 Plus的接线盒
16信道4线AI
系列2 Plus的接线盒
冗余2线和4线
接线板
48引脚AI质量终端
系列2 Plus的块
冗余48引脚
人工智能大规模终止
系列2 Plus的块
AO,8通道,4-20 mA,HART A4输入/输出端子板
熔断接线板
16引脚质量接线板
AO Plus,16通道,4-20 mA,HART A5 16通道AO
系列2 Plus的接线盒
冗余16通道AO
系列2 Plus的接线盒
48针AO质量
系列2 Plus的接线盒
冗余48引脚AO质量
系列2 Plus的接线盒
热电偶,中压C1输入/输出端子板
冷端补偿(CJC)
接线板
NA
RTD,8通道C3电阻温度装置
(RTD)接线板
NA
隔离输入卡C2隔离输入端子块NA
DI,8通道,24V直流,干触点B1输入/输出端子板
熔断接线板
16引脚质量接线板
DI,8通道,24V直流,隔离B2输入/输出端子板
熔断接线板
16引脚质量接线板
DI,32通道,24V直流,干触点B3,32通道接线盒,40针质量接线盒
DI Plus,32通道,24V直流,
干接触
E3 32信道DI
系列2 Plus的接线盒
冗余32通道DI
系列2 Plus的接线盒
40引脚DI质量
系列2 Plus的接线盒
冗余40引脚DI质量
系列2 Plus的接线盒
PCI,4通道C6 32通道接线板NA
SOE,16通道,24V直流C5 32通道接线板,40引脚质量接线板
DO,8通道,24V直流,高压侧B6输入/输出端子板
熔断接线板
10引脚质量接线板
16引脚质量终端块通道,120/230V交流,高压侧。
DeltaV M系列传统I/O,2022年8月
www.emerson。com/deltav 27
I/O接线板
可提供各种I/O端子块,以满足特定要求
功能和环境要求
安装I/O接口是I/O卡的组合
以及I/O端子块。每个I/O接口都有的键控
使得一旦安装在具有端子块的载体槽中,
该接线板将仅接受替换卡。
8通道标准接线盒。
键控机构由两个旋转的键控柱组成
并锁定在接线盒底座中。每个职位有6个职位:
A-F和1-6。每张卡都分配了一个的密钥,并标记
在I/O卡的一侧:
终端块键控示例。
键可防止安装不正确的卡,并且
卡上的图形信息便于确定
如果钥匙槽将接受特定卡。
有不同的I/O端子块可用于满足
现场信号的布线需求。
8通道接线盒
熔断8通道接线盒
AI 8通道接线盒
2线AI加16通道接线板
4线AI加16通道接线板
AO Plus 16通道接线盒
DI 32通道接线盒
DI Plus 32通道接线盒
DO Plus 32通道接线盒
隔离输入端子排
RTD/电阻接线盒
热电偶接线盒
以下冗余I/O端子块可用:
在某些I/O接口上,允许安装一对卡
作为冗余对。
冗余AI 8通道接线盒
冗余AI加16通道接线盒
冗余AO 8通道接线盒
冗余AO加16通道接线盒
冗余离散8通道接线盒
冗余DI加32通道接线盒
冗余DO加32通道接线盒
下页的表列出了兼容的
每个卡的接线板以及卡
独特的关键位置。列出的一个端子排
是推荐的接线板。
除标准信号布线外,某些板卡还可能
订购允许这些卡的大量接线板
连接到M系列质量连接解决方案
或来自Phoenix的三方布线解决方案或if IS屏障
由Pepperl和Fuchs提供,安装在相邻的
满足特殊信号调节或优化的机柜
现场布线解决方案。请参阅联盟计划
网站,以获取关于已批准的三方产品的详细信息。
10针质量接线盒(仅单工)
16针质量接线盒(仅单工)
24针质量接线盒(仅单工)
40引脚质量接线板(单工和冗余)
48针质量接线盒(单工和冗余)通道,24V直流,隔离。
DeltaV M系列传统I/O,2022年8月
www.emerson。com/deltav 21
SOE板卡规格,16通道,24V直流,干触点
信道数16
D
KJ3243X1-BA1

KJ3243X1-BA1
I/O Card I/O Card Keying Traditional I/O Terminal Blocks Mass Termination Blocks
AI, 8-Channel, 4–20 mA, HART A1 I/O terminal block
Fused I/O terminal block
4-wire I/O terminal block
16-pin Mass termination block
(Supports 2-wire Devices)
24-pin Mass termination block
(Supports 4-wire Devices)
AI Plus, 16-Channel, 4-20 mA, HART A6 16-Channel 2-Wire AI
terminal block for Series 2 Plus
16-Channel 4-Wire AI
terminal block for Series 2 Plus
Redundant 2- & 4-Wire
terminal block
48-pin AI Mass termination
block for Series 2 Plus
Redundant 48-pin
AI Mass termination
block for Series 2 Plus
AO, 8-Channel, 4–20 mA, HART A4 I/O terminal block
Fused terminal block
16-pin Mass termination block
AO Plus, 16-Channel, 4-20 mA, HART A5 16-Channel AO
terminal block for Series 2 Plus
Redundant 16-Channel AO
terminal block for Series 2 Plus
48-pin AO Mass
termination block for Series 2 Plus
Redundant 48-pin AO Mass
termination block for Series 2 Plus
Thermocouple, mV C1 I/O terminal block
Cold Junction Compensated (CJC)
terminal block
NA
RTD, 8-Channel C3 Resistant Temperature Device
(RTD) terminal block
NA
Isolated Input Card C2 Isolated Input terminal block NA
DI, 8-Channel, 24V DC, Dry Contact B1 I/O terminal block
Fused terminal block
16-pin Mass termination block
DI, 8-Channel, 24V DC, Isolated B2 I/O terminal block
Fused terminal block
16-pin Mass termination block
DI, 32-Channel, 24V DC, Dry Contact B3 32-Channel terminal block 40-pin Mass termination block
DI Plus, 32-Channel, 24V DC,
Dry Contact
E3 32-Channel DI
terminal block for Series 2 Plus
Redundant 32-Channel DI
terminal block for Series 2 Plus
40-pin DI Mass
termination block for Series 2 Plus
Redundant 40-pin DI Mass
termination block for Series 2 Plus
PCI, 4-Channel C6 32-Channel terminal block NA
SOE, 16-Channel, 24V DC C5 32-Channel terminal block 40-pin Mass termination block
DO, 8-Channel, 24V DC, High-Side B6 I/O terminal block
Fused terminal block
10-pin Mass termination block
16-pin Mass termination blockchannel,120/230V AC, High-Side.
DeltaV M-series Traditional I/O August 2022
www.emerson.com/deltav 27
I/O Terminal Blocks
A variety of I/O terminal blocks are available to meet specific
functionality and environmental requirements of the
installation. The I/O interface is a combination of the I/O card
and the I/O terminal block. Each I/O interface is uniquely keyed
so that once installed in a carrier slot with a terminal block,
that terminal block will only accept a replacement card.
8-channel standard terminal block.
The keying mechanism consists of two keying posts that rotate
and lock into the terminal block base. Each post has 6 positions:
A-F and 1-6. Each card is assigned a unique key, which is marked
on the side of the I/O card:
Terminal block keying example.
The keys prevent installation of an incorrect card, and the
graphical information on the card makes it easy to determine
if a keyed slot will accept a particular card.
There are different I/O terminal blocks available to meet the
wiring needs of field signals.
8-Channel terminal block
Fused 8-Channel terminal block
AI 8-Channel terminal block
2-wire AI Plus 16-Channel terminal block
4-wire AI Plus 16-Channel terminal block
AO Plus 16-Channel terminal block
DI 32-Channel terminal block
DI Plus 32-Channel terminal block
DO Plus 32-Channel terminal block
Isolated Input terminal block
RTD/Resistance terminal block
Thermocouple terminal block
The following redundant I/O terminal blocks are available
on some I/O interfaces, allowing a pair of cards to be installed
as a redundant pair.
Redundant AI 8-Channel terminal block
Redundant AI Plus 16-Channel terminal block
Redundant AO 8-Channel terminal block
Redundant AO Plus 16-Channel terminal block
Redundant Discrete 8-Channel terminal block
Redundant DI Plus 32-Channel terminal block
Redundant DO Plus 32-Channel terminal block
The table on the following page lists the compatible
terminal blocks for each card, along with the cards
unique key positions. The first terminal block listed
is the recommended terminal block.
In addition to standard signal wiring, some cards may also
be ordered with Mass Terminal blocks that allow these cards
to be connected to the M-series Mass Connection Solutions
or third party wiring solutions from Phoenix or if IS Barriers
are required from Pepperl and Fuchs, mounted in an adjacent
cabinet to meet special signal conditioning or for optimizing
field wiring solutions. Please refer to the Alliance Program
website for details on approved third-party products.
10-pin Mass Termination Block (simplex only)
16-pin Mass Termination Block (simplex only)
24-pin Mass Termination Block (simplex only)
40-pin Mass Termination Block (simplex and redundant)
48-pin Mass Termination Block (simplex and redundant)channel, 24V DC, Isolated.
DeltaV M-series Traditional I/O August 2022
www.emerson.com/deltav 21
Specifications for SOE Card, 16-channel, 24V DC, Dry Contact
Number of Channels 16
Detection Level for On >2 mA
Detection Level for Off <0.25 mA
Input Impedance 5K ohm (approximate)
Wetting Voltage 24V DC
Channel Scan Rate 0.25 msec for all 16 channels
Time Stamp Accuracy (for SOE enabled channels only)* 0.25 msec from same card
1 msec from same controller
LocalBus Current (12V DC nominal) 75 mA typical, 100 mA maximum
Field Circuit Power per Card 75 mA at 24V DC
Isolation Each channel is optically isolated from the system
and factory tested to 1500V DC