MSK101E-0200-NN-S1-AG0-NNNN模块现货

型号: MSK101E-0200-NN-S1-AG0-NNNN  分类: foxboro
  • MSK101E-0200-NN-S1-AG0-NNNN
  • MSK101E-0200-NN-S1-AG0-NNNN
  • MSK101E-0200-NN-S1-AG0-NNNN
  • MSK101E-0200-NN-S1-AG0-NNNN
  • MSK101E-0200-NN-S1-AG0-NNNN


MSK101E-0200-NN-S1-AG0-NNNN模块现货 MSK101E-0200-NN-S1-AG0-NNNN模块现货 MSK101E-0200-NN-S1-AG0-NNNN模块现货 MSK101E-0200-NN-S1-AG0-NNNN模块现货 MSK101E-0200-NN-S1-AG0-NNNN模块现货




 

MSK101E-0200-NN-S1-AG0-NNNN

MVME162上多可安装四个工业包(IP)模块。
在MVME162上安装IPs,如下所示:
1.每个IP有两个50针连接器,插入两个相应的50-
MVME162上的引脚连接器:J2/J3、J7/J8、J13/J14、J18/J19。见图
MVME162连接器位置见2-1。
–调整仪表板的方向,使锥形连接器外壳正确配合。
将IP_a插入连接器J2和J3;将IP_b插入J7和J8。插入IP_c
转换成J13和J14;将IP_d插入J18和J19。如果双尺寸IP
使用时,将IP_ab插入J2、J3、J7和J8;将IP_cd插入J13、J14、J18和
J19。
2.后面提供了四个额外的50针连接器(J6、J5、J17和J16)
MVME162前面板用于连接至IP的外部电缆
模块。上的信号之间存在一对一的对应关系
电缆连接器和相关IP连接器上的信号(即J6
具有与J2相同的IP_ a信号;J5具有与J7相同的IP_ b信号;J17已经
与J13相同的IP_ c信号;并且J16具有与J18相同的IP_ d信号。
–根据需要将用户提供的50针电缆连接到J6、J5、J17和J16。
由于对每种不同类型IP的不同要求,
摩托罗拉不提供这些电缆。
–将IP电缆从MVME162前面板的窄槽中取出
并将其连接到适当的外部设备,具体取决于
特定IP的性质。
硬件准备和安装
2-10 MVME162嵌入式控制器用户手册
2 MVME162模块安装
安装了EPROM和IndustryPack并正确配置了头,
按照以下步骤在VME机箱中安装MVME162:
1.关闭所有设备电源,并从
交流电源。
注意:通电时插入或移除模块
可能导致模块部件损坏。
!
警告
可能导致死亡的危险电压存在于
这个设备。在操作、测试和调整时应格外小心。
2.按照用户手册中的说明卸下机箱盖
设备
3.从要安装的卡槽中卸下填充面板
MVME162。
–如果您打算使用MVME162作为系统控制器,它必须占用
左边的卡插槽(插槽1)。系统控制器必须位于插槽1中
要正确启动总线授予菊花链,并确保正确
IACK菊花链驱动器的操作。
–如果您不打算使用MVME162作为系统控制器,它可以
占用任何未使用的双高卡插槽。
4.将MVME162滑入所选卡槽。确保模块是
正确安装在底板上的P1和P2连接器中。不要
损坏或弯曲连接器引脚。
5.使用提供的螺钉将MVME162固定在机箱中,使
与横向安装轨道良好接触,以尽量减少射频
排放。
6.将MVME712系列过渡模块安装在
VME机箱。(要安装MVME712M,其具有双宽前部
面板,您可能需要移动机箱中的其他模块。)
7.在机箱底板上,移除中断确认
(IACK)和总线授权(BG)跳线,从卡插槽的头部
被MVME162占用

MSK101E-0200-NN-S1-AG0-NNNN

MSK101E-0200-NN-S1-AG0-NNNN模块现货

MSK101E-0200-NN-S1-AG0-NNNN

 to four IndustryPack (IP) modules may be installed on the MVME162.
Install the IPs on the MVME162 as follows:
1. Each IP has two 50-pin connectors that plug into two corresponding 50-
pin connectors on the MVME162: J2/J3, J7/J8, J13/J14, J18/J19. See Figure
2-1 for the MVME162 connector locations.
– Orient the IP(s) so that the tapered connector shells mate properly.
Plug IP_a into connectors J2 and J3; plug IP_b into J7 and J8. Plug IP_c
into J13 and J14; plug IP_d into J18 and J19. If a double-sized IP is
used, plug IP_ab into J2, J3, J7, and J8; plug IP_cd into J13, J14, J18, and
J19.
2. Four additional 50-pin connectors (J6, J5, J17, and J16) are provided behind
the MVME162 front panel for external cabling connections to the IP
modules. There is a one-to-one correspondence between the signals on the
cabling connectors and the signals on the associated IP connectors (i.e., J6
has the same IP_a signals as J2; J5 has the same IP_b signals as J7; J17 has
the same IP_c signals as J13; and J16 has the same IP_d signals as J18.
– Connect user-supplied 50-pin cables to J6, J5, J17, and J16 as needed.
Because of the varying requirements for each different kind of IP,
Motorola does not supply these cables.
– Bring the IP cables out the narrow slots in the MVME162 front panel
and attach them to the appropriate external equipment, depending on
the nature of the particular IP(s).
Hardware Preparation and Installation
2-10 MVME162 Embedded Controller User’s Manual
2 MVME162 Module Installation
With EPROM and IndustryPacks installed and headers properly configured,
proceed as follows to install the MVME162 in the VME chassis:
1. Turn all equipment power OFF and disconnect the power cable from the
AC power source.
Caution Inserting or removing modules while power is applied
could result in damage to module components.
!
WARNING
Dangerous voltages, capable of causing death, are present in
this equipment. Use extreme caution when handling, testing, and adjusting.
2. Remove the chassis cover as instructed in the user’s manual for the
equipment.
3. Remove the filler panel from the card slot where you are going to install
the MVME162.
– If you intend to use the MVME162 as system controller, it must occupy
the leftmost card slot (slot 1). The system controller must be in slot 1
to correctly initiate the bus-grant daisy-chain and to ensure proper
operation of the IACK daisy-chain driver.
– If you do not intend to use the MVME162 as system controller, it can
occupy any unused double-height card slot.
4. Slide the MVME162 into the selected card slot. Be sure the module is
seated properly in the P1 and P2 connectors on the backplane. Do not
damage or bend connector pins.
5. Secure the MVME162 in the chassis with the screws provided, making
good contact with the transverse mounting rails to minimize RF
emissions.
6. Install the MVME712 series transition module in the front or the rear of the
VME chassis. (To install an MVME712M, which has a double-wide front
panel, you may need to shift other modules in the chassis.)
7. On the chassis backplane, remove the INTERRUPT ACKNOWLEDGE
(IACK) and BUS GRANT (BG) jumpers from the header for the card slot
occupied by the MVME162