使用以下步骤连接可充电外部电池单元:
1.交付时,锂离子电池组内部未连接。追随
包装箱中的数据和安装表中的步骤:
正确连接电池组。
2.将SB822可充电外部电池单元安装在适当位置
DIN导轨。
3.将24V电源连接至包装箱内的连接器。
4.将24V电源连接到电池单元(X3)
5.确保AC 800M控制器已通电,且电池已接通
PM8xx的前端正在闪烁
6.连接SB822可充电外部电池单元,使用2米(2.2码)
电缆TK821V020。将一端插入电池单元,另一端插入
PM8xx处理器单元的外部电池电源插座(参见上的图2
32页)。
7.确保SB822上的绿色电源指示灯和黄色充电指示灯
被打开。
8.在冗余CPU配置中,包含两个
PM861/PM864/PM865/PM891处理器单元,也使用两个SB822电池
每个处理器单元一个。
9.由于电池并联,在使用
外部电池,从PM8xx上拆下内部电池,以便
避免减少可用内存和备份时间。
在安装AC 800M控制器之前,不要连接TK821V020电缆
正常通电且存储器备份功能已激活,
B(蓄电池)LED闪烁。如果PM8xx未连接正常电源
处理器单元,CPU内存将立即开始消耗电池电量
连接电缆时
2节安装I/O装置的安装
3BSE036351-510 A 145
I/O装置的安装
有关安装、拆卸和释放程序的更多信息,请参阅
输入/输出装置,请参阅相应的输入/输出系统文档。
柜内安装
下图是AC 800M控制器如何供电的示例
电源单元、表决单元和S800 I/O单元可配置和安装在
橱柜:
•146页图49:壁柜-单电源布置
•147页图50:壁柜-双电源(本地/现场)
安排
•148页图51:落地式机柜-装置布置
(冗余PSU)
DIN导轨采用支撑铝型材,以确保刚性。
参见403页的图118。
图中所示的机柜为ABB制造的机柜:
•RE820:壁柜
•RM550:落地柜
柜内安装2节安装
146 3BSE036351-510 A
图49.壁柜-单电源布置
24V配电
终端
电源断路器SD831
单元
缆绳


轮廓
缆绳
膨胀
模块总线
2节安装:柜内安装
3BSE036351-510 A 147
图50.壁柜-双电源(本地/现场)布置
电源断路器
单元
SD831
24V配电
(单位)
(柜内装置)
SD831
(现场)
24V配电
(现场设备)
柜内安装2节安装
148 3BSE036351-510 A
图51.落地式机柜(水平单元布置)
投票
单位
SS832断路器
干线
SD832冗余
电源装置
冗余的
权力
供应单位
(现场
设备)
SD832
2节适当通风的安装安装尺寸
3BSE036351-510 A 149
适当通风的安装尺寸
为了保持足够的冷却气流通过AC 800M控制器单元,有
装置上方50mm(2英寸)和下方25mm(1英寸)范围内不得有障碍物,
如149页图52所示。请注意,CPU和通信
接口必须安装在水平DIN导轨上。
35AE90E-E GJR5132400R0028 35AE90 驱动器PCB板卡 

35AE90E-E GJR5132400R0028 35AE90 驱动器PCB板卡

35AE90E-E GJR5132400R0028 35AE90 驱动器PCB板卡 

Use the following procedure to connect the rechargeable external battery unit:
1. At delivery the Li-Ion battery package is not connected internally. Follow the
steps in the Data and installation sheet, which is enclosed in the packing box, to
connect the battery package properly.
2. Mount the SB822 rechargeable external battery unit at a suitable position on
the DIN-rail.
3. Connect the 24V supply to the connector enclosed in the packing box.
4. Connect the 24V supply to the battery unit (X3)
5. Make sure that the AC 800M controller is powered and that the battery LED in
the front of PM8xx is flashing
6. Connect the SB822 rechargeable external battery unit, use the 2 m (2.2 yd)
cable TK821V020. Plug one end into the battery unit and the other into the
external battery supply socket of the PM8xx processor unit (see Figure 2 on
page 32).
7. Make sure that the green Power LED and the yellow Charge LED on SB822
are turned on.
8. In redundant CPU configuration containing two
PM861/PM864/PM865/PM891processor units, use also two SB822 battery
units, one for each processor unit.
9. Due to the batteries being connected in parallel, it is necessary, when using the
external battery, to remove the internal battery from the PM8xx in order to
avoid reducing available memory back-up time.
Do not connect the TK821V020 cable until the AC 800M Controller has been
powered-up normally and the memory back-up function has been activated, that is,
the B(attery) LED flashes. If no normal power supply is connected to the PM8xx
processor unit, the CPU memory will immediately start to consume battery power
when the cable is connected
Section 2 Installation Installation of I/O Units
3BSE036351-510 A 145
Installation of I/O Units
For further information regarding mounting, removing and releasing procedures for
I/O Units, refer to the appropriate I/O system documentation.
Installation in Cabinets
The figures listed below are examples of how the AC 800M Controllers, Power
Supply units, Voting units and S800 I/O units can be configured and mounted within
cabinets:
• Figure 49 on page 146: Wall Cabinet – Single Power Supply Arrangement
• Figure 50 on page 147: Wall Cabinet – Dual Power Supply (Local/Field)
Arrangement
• Figure 51 on page 148: Floor Mounted Cabinet – Unit Arrangement
(Redundant PSU)
The DIN-rails are using the supporting Al-profile to ensure rigidness.
See Figure 118 on page 403.
The cabinets shown in the figures are ABB manufactured cabinets:
• RE820: Wall Cabinet
• RM550: Floor Cabinet
Installation in Cabinets Section 2 Installation
146 3BSE036351-510 A
Figure 49. Wall Cabinet – Single Power Supply Arrangement
24 V Distribution
Terminals
Mains Breaker SD831
Unit
Cable
Duct
Aluminum
Profile
Cable
Expansion
ModuleBus
Section 2 Installation Installation in Cabinets
3BSE036351-510 A 147
Figure 50. Wall Cabinet – Dual Power Supply (Local/Field) Arrangement
Mains Breaker
Unit
SD831
24 V Distribution
(Units)
(Units in Cabinet)
SD831
(Field)
24 V Distribution
(Field Equipment)
Installation in Cabinets Section 2 Installation
148 3BSE036351-510 A
Figure 51. Floor Mounted Cabinet (Horizontal Unit Arrangement)
Voting
Units
SS832 Breakers
Mains
SD832 Redundant
Power Supply Units
Redundant
Power
Supply Units
(Field
Equipment)
SD832
Section 2 Installation Mounting Dimensions for Proper Ventilation
3BSE036351-510 A 149
Mounting Dimensions for Proper Ventilation
To maintain adequate cooling airflow through the AC 800M Controller units, there
must be no obstruction within 50 mm (2 in) above and 25 mm (1 in) below the units,
as shown in Figure 52 on page 149. Note that the CPU and Communication
Interfaces must be mounted on a horizontal DIN-rail.