5SHY4045L0001 3BHB018162R0001 3BHE009681R0101 GVC7 RDRE1 BI#1 触发或 PHLPTOC1启动 PHHPTOC1启动 PHHPTOC2启动 PHIPTOC1启动 NSPTOC1启动 NSPTOC2启动 DEFLPDEF1启动 EFPADM1启动 WPWDE1启动 或 DEFLPDEF2启动 EFPADM2启动 WPWDE2启动 或 DEFHPDEF1启动 EFPADM3启动 WPWDE3启动 INTRPTEF1开始 EFHPTOC1启动 PDNSPTOC1启动 T1PTTR1启动 ROVPTOV1启动 ROVPTOV2启动 ROVPTOV3启动 CCBRBRF1 trret CCBRBRF1 trbu或 INTRPTEF1操作EFHPTOC1操作PDNSPTOC1操作T1PTTR1操作INRPHAR1-blk2h或 PHLPTOC1运行PHHPTOC1运行PHHPTOC2运行PHIPTOC1运行NSPTOC1运行NSPTOC运行 或 DEFLPDEF1操作DEFLPDEF2操作DEFHPDEF1操作EFPADM1操作EFPADM2操作EFPADM3操作或 WPWDE3操作或 或 ROVPTOV1操作WPWDE2操作WPWDE1操作ROVPTOV2操作ROVPTOV3操作或 ARCSARC1-arc_flt_det ARCSARC2-arc_flt_det ARCSARC3-arc_flt_det ARCSARC1运行ARCSARC2运行ARCSARC3运行DARREC1 inpro DARREC2-close_cb DARREC1-UNSC_recl TCSCBR2闭塞报警 BI 1(阻塞) BI 2(断路器关闭) BI 3(断路器开路) TRPPTRC1-跳闸或 TRPPTRC2-跳闸 TCSCBR1阻塞报警或LED9(TCS报警) 干扰记录器 A071324 V6 EN 图26:干扰记录器 来自保护级的所有启动和运行信号都被路由以触发 干扰记录器,或仅由干扰记录 记录器取决于参数设置。此外,选择 自动重合闸、电弧保护信号和X120的三个二进制输入为 也连接。 包括两个独立的跳闸电路监控功能,用于PO3的TCSCBR1 (X100:15-19)和用于PO4的TCSCBr2(X100:20-24)。两个功能都被阻止 通过主跳闸(TRPPTRC1和TRPPTRC2)和断路器断开 信号TCS报警指示连接至LED 9。 第3节1MRS756378 K REF615标准配置 62参考文献615 应用手册 默认情况下,预期中没有外部电阻器 断路器跳闸线圈电路与电路并联 断路器常开辅助触点。 3.5.3.3控制和联锁功能图 PHLPTOC1运行PHHPTOC1运行PHHPTOC2运行PHIPTOC1运行NSPTOC1运行NSPTOC运行 PDNSPTOC1操作DEFLPDEF1操作EFHPTOC1跳闸线圈1 PO3 TRPPTRC1块操作RST_LKOUT 带锁定模式选择的跳闸CL_LKOUT TRPPTRC2块操作RST_LKOUT 带锁定模式选择的跳闸CL_LKOUT DARREC1开路断路器 CBXCBR1-exe_op 主跳闸#2 DEFLPDEF2操作DEFHPDEF1操作EFPADM1操作EFPADM2操作EFPADM3操作INTRPTEF1操作ROVPTOV1操作ROVPTOV3操作ROVPTOV2操作ARCSARC1操作ARCSARC2操作ARCSARC3操作 PHLPTOC1运行PHHPTOC1运行PHHPTOC2运行PHIPTOC1运行NSPTOC1运行NSPTOC运行 PDNSPTOC1操作DEFLPDEF1操作EFHPTOC1操作或 DEFLPDEF2操作DEFHPDEF1操作EFPADM1操作EFPADM2操作EFPADM3操作INTRPTEF1操作ROVPTOV1操作ROVPTOV3操作ROVPTOV2操作ARCSARC1操作ARCSARC2操作ARCSARC3操作CCBRBRF1 trret WPWDE1操作WPWDE2操作WPWDE3操作 WPWDE1操作WPWDE2操作WPWDE3操作 开路断路器/ 跳闸线圈2 A071326 V6 EN 图27:主跳闸 来自保护装置的操作信号连接至双跳闸输出 通过相应的主设备联系PO3(X100:15-19)和PO4(X100:20-24) 跳闸TRPPTRC1和TRPPTRC2。断路器的断开控制命令 从本地或远程CBXCBR1-exe_op或自动重合闸器DARREC1- open_ cb直接连接到输出PO3(X100:15-19)。 TRPPTRC1和2提供锁定/闭锁功能、事件生成和 跳闸信号持续时间设置。如果选择了锁定操作模式,一个二进制有两种类型的隔离开关和接地开关块可用。 DCSXSWI1…3和ESSSWI1…2仅为状态类型,而DCXSWI1…2和 ESXSWI1为可控型。默认情况下,仅连接状态块 标准配置逻辑。如果可控操作,则可控 可以使用隔离开关和接地开关块的类型,而不是状态 这是的类型。可以完成控制块的连接和配置 使用PCM600。 附加卡X110的二进制输入5和6用于母线 隔离开关(DCSXSWI1)或断路器支架位置指示。 表20:二进制输入5和6表示的设备位置 待通电的一次设备位置输入 输入5(X110:8-9)输入6(X110:10-9) 母线隔离开关闭合x 母线隔离开关断开x 断路器台车处于工作位置x 断路器台车处于测试位置x 第3节1MRS756378 K REF615标准配置 64参考文献615 应用手册 二进制输入7和8(X110:11-13)用于以下位置指示: 线路侧接地开关。 当ENA_CLOSE输入激活时,断路器闭合被启用。 输入可由配置逻辑激活,配置逻辑是 隔离开关或 5SHY4045L0001 3BHB018162R0001 3BHE009681R0101 GVC7 5SHY4045L0001 3BHB018162R0001 3BHE009681R0101 GVC7 RDRE1 BI#1 TRIGGERED OR PHLPTOC1-start PHHPTOC1-start PHHPTOC2-start PHIPTOC1-start NSPTOC1-start NSPTOC2-start DEFLPDEF1-start EFPADM1-start WPWDE1-start OR DEFLPDEF2-start EFPADM2-start WPWDE2-start OR DEFHPDEF1-start EFPADM3-start WPWDE3-start INTRPTEF1-start EFHPTOC1-start PDNSPTOC1-start T1PTTR1-start ROVPTOV1-start ROVPTOV2-start ROVPTOV3-start CCBRBRF1-trret CCBRBRF1-trbu OR INTRPTEF1-operate EFHPTOC1-operate PDNSPTOC1-operate T1PTTR1-operate INRPHAR1-blk2h OR PHLPTOC1-operate PHHPTOC1-operate PHHPTOC2-operate PHIPTOC1-operate NSPTOC1-operate NSPTOC2-operate OR DEFLPDEF1-operate DEFLPDEF2-operate DEFHPDEF1-operate EFPADM1-operate EFPADM2-operate EFPADM3-operate OR WPWDE3-operate OR OR ROVPTOV1-operate WPWDE2-operate WPWDE1-operate ROVPTOV2-operate ROVPTOV3-operate OR ARCSARC1-arc_flt_det ARCSARC2-arc_flt_det ARCSARC3-arc_flt_det ARCSARC1-operate ARCSARC2-operate ARCSARC3-operate DARREC1-inpro DARREC1-close_cb DARREC1-unsuc_recl TCSSCBR2 BLOCK ALARM BI 1 (Blocking) BI 2 (CB Closed) BI 3 (CB Open) TRPPTRC1 - trip OR TRPPTRC2 - trip TCSSCBR1 BLOCK ALARM OR LED9 (TCS ALARM) DISTURBANCE RECORDER A071324 V6 EN Figure 26: Disturbance recorder All start and operate signals from the protection stages are routed to trigger the disturbance recorder or alternatively only to be recorded by the disturbance recorder depending on the parameter settings. Additionally, the selected autorecloser, the ARC protection signals and the three binary inputs from X120 are also connected. Two separate trip circuit supervision functions are included, TCSSCBR1 for PO3 (X100:15-19) and TCSSCBR2 for PO4 (X100:20-24). Both functions are blocked by the Master Trip (TRPPTRC1 and TRPPTRC2) and the circuit breaker open signal. The TCS alarm indication is connected to LED 9. Section 3 1MRS756378 K REF615 standard configurations 62 REF615 Application Manual By default it is expected that there is no external resistor in the circuit breaker tripping coil circuit connected parallel with circuit breaker normally open auxiliary contact. 3.5.3.3 Functional diagrams for control and interlocking PHLPTOC1-operate PHHPTOC1-operate PHHPTOC2-operate PHIPTOC1-operate NSPTOC1-operate NSPTOC2-operate PDNSPTOC1-operate DEFLPDEF1-operate EFHPTOC1-trip coil 1 PO3 TRPPTRC1 BLOCK OPERATE RST_LKOUT TRIP CL_LKOUT With lock-out mode selection TRPPTRC2 BLOCK OPERATE RST_LKOUT TRIP CL_LKOUT With lock-out mode selection DARREC1-open cb CBXCBR1-exe_op MASTER TRIP #2 DEFLPDEF2-operate DEFHPDEF1-operate EFPADM1-operate EFPADM2-operate EFPADM3-operate INTRPTEF1-operate ROVPTOV1-operate ROVPTOV3-operate ROVPTOV2-operate ARCSARC1-operate ARCSARC2-operate ARCSARC3-operate PHLPTOC1-operate PHHPTOC1-operate PHHPTOC2-operate PHIPTOC1-operate NSPTOC1-operate NSPTOC2-operate PDNSPTOC1-operate DEFLPDEF1-operate EFHPTOC1-operate OR DEFLPDEF2-operate DEFHPDEF1-operate EFPADM1-operate EFPADM2-operate EFPADM3-operate INTRPTEF1-operate ROVPTOV1-operate ROVPTOV3-operate ROVPTOV2-operate ARCSARC1-operate ARCSARC2-operate ARCSARC3-operate CCBRBRF1-trret WPWDE1-operate WPWDE2-operate WPWDE3-operate WPWDE1-operate WPWDE2-operate WPWDE3-operate Open CB / trip coil 2 A071326 V6 EN Figure 27: Master trip The operate signals from the protections are connected to the two trip output contacts PO3 (X100:15-19) and PO4 (X100:20-24) via the corresponding Master Trips TRPPTRC1 and TRPPTRC2. Open control commands to the circuit breaker from local or remote CBXCBR1-exe_op or from the auto-recloser DARREC1- open_cb are connected directly to the output PO3 (X100:15-19). TRPPTRC1 and 2 provide the lockout/latching function, event generation and the trip signal duration setting. If the lockout operation mode is selected, one binaryThere are two types of disconnector and earthing switch blocks available. DCSXSWI1...3 and ESSXSWI1...2 are status only type, and DCXSWI1...2 and ESXSWI1 are controllable type. By default, the status only blocks are connected in standard configuration logic. If controllable operation is preferred, the controllable type of disconnector and earthing switch blocks | 5SHY4045L0001 3BHB018162R0001 3BHE009681R0101 GVC7 | | | |