




产品标题:ENTERASYS 24端口可堆叠L2/L3边缘交换机 A2H124-24FX P0973BJ
型号: 24端口可堆叠L2/L3边缘交换机 A2H124-24FX P0973BJ
品牌:ENTERASYS
质保:七天验收期,质保期一年
发货期:1-3个工作日
产品图片展示
产品详情资料
DCS 500
DCS 500适用于DCS 500B/DCS 600/DCF 500B/DCF 600
Îy型变流器→ y=4(400伏)y=5(500伏)y=6(600伏)y=7(690伏)y=8(790伏)y=9(1000伏)
Ð
x=1→ 2-Q IDC[A][W][W][W][W][W][W]
x=2→ 4-Q 4Q 2Q PV-I PV-U PV-I
DCS50x-0025-Y125 25 25 60 30 60 47
DCS50x-0050-y1 50 50 123 30 123 47
DCS50x-0050-61 50 50 108 46
DCS50x-0075-y1 75 75 175 30 175 47
DCS50x-0100-y1 100 100 207 50 207 70
DCS50x-0110-61 110 100 284 100
DCS50x-0140-Y1140 125 311 50 311 70
DCS50x-0200-Y1200 180 488 50 488 70
DCS50x-0250-Y1250 225 656 50 656 70
DCS50x-0270-61 270 245 781 100
DCS50x-0350-y1 350 315 840 50 840 70
DCS50x-0450-Y1450 405 1040 70 1040 80 1119 110
DCS50x-0520-Y1520 470 1238 70 1238 80
DCS50x-0680-y1 680 610 1622 105 1622 140
DCS50x-0820-Y18207401986 125 1986 160
DCS50x-1000-y1 1000 900 2527 125 2527 160
DCS50x-0903-Y1900 900 4190 930 4190 1170
DCS50x-1203-Y11200 1200 4510 420 4510 600
DCS50x-1503-Y11500 1500 4740 460 4740 640 5540 850 5540 1080
DCS50x-2003-y1 2000 2000 5950 470 5950 660 6820 1100 6820 1370
DCS50x-1903-811900 1900 71501800
DCS50x-2053-Y12050 2050 7160 880 8050 1140 8050 1410 7300 1820
DCS501-2503-y1 2500 8250 590 8250 800 8930 1220 8930 1510 8930 1830
DCS502-2503-y1 2500 8400 900 7820 1200 8400 1510 8400 1850 8400 2210
DCS501-3003-y1 3000 9570 450 9750 620 9430 1410 9430 1740 9430 2090
DCS502-3003-y1 3000 9900 900 9900 1200 10300 1510 10300 1850 10300 2210
DCS50x-2053-91 2050 2050 7090 2630
DCS50x-2603-91 2600 2600 9420 2690
DCS50x-3303-y1 3300 3300 10850 570 10850 780 11700 1190 11700 1470 11700 1780 11600 4650
DCS50x-4003-y1 4000 12300 480 12300 660 13350 1520 13350 1860 13350 2230 15400 4800
DCS50x-4803-Y14800 4800 16800 2300 16800 2750 16800 3250
DCS50x-5203-Y15200 5200 17250 1390 17250 1800
表2.4/1:DCS 500功率损耗
III 2-14
3ADW000165R0201_Technical_Data_e_b
2.5动力段冷却
DCS 500的风机分配
DCS 500的风机数据
DCS 500的风机连接
表2.5/2:DCS 500的风机数据
表2.5/1:DCS 500的风机分配
三、2-15
3ADW000165R0201_Technical_Data_e_b
监控DCS 500电源段
它不是安装在散热器上,而是靠近
风扇出风口。检测器因此测量
功率部分的辐射热和任何变化
在冷却空气温度和体积。自从
只能检测冷却空气量
间接地,压差开关已经
额外安装在装置外壳上,始终
靠近电源端子。
电阻变化与
在中获取和评估温度
该单元的软件。如果温度高于
参数化值,则首先报警
输出,如果温度持续
里斯DCS 500
DCS 500 valid for DCS 500B / DCS 600 / DCF 500B / DCF 600
Converter type Î y → y=4 (400 V) y=5 (500 V) y=6 (600 V) y=7 (690 V) y=8 (790 V) y=9 (1000V)
Ð
x=1 → 2-Q IDC [A] [W] [W] [W] [W] [W] [W]
x=2 → 4-Q 4Q 2Q PV-I PV-U PV-I PV-U PV-I PV-U PV-I PV-U PV-I PV-U PV-I PV-U
DCS50x-0025-y1 25 25 60 30 60 47
DCS50x-0050-y1 50 50 123 30 123 47
DCS50x-0050-61 50 50 108 46
DCS50x-0075-y1 75 75 175 30 175 47
DCS50x-0100-y1 100 100 207 50 207 70
DCS50x-0110-61 110 100 284 100
DCS50x-0140-y1 140 125 311 50 311 70
DCS50x-0200-y1 200 180 488 50 488 70
DCS50x-0250-y1 250 225 656 50 656 70
DCS50x-0270-61 270 245 781 100
DCS50x-0350-y1 350 315 840 50 840 70
DCS50x-0450-y1 450 405 1040 70 1040 80 1119 110
DCS50x-0520-y1 520 470 1238 70 1238 80
DCS50x-0680-y1 680 610 1622 105 1622 140
DCS50x-0820-y1 820 740 1986 125 1986 160
DCS50x-1000-y1 1000 900 2527 125 2527 160
DCS50x-0903-y1 900 900 4190 930 4190 1170
DCS50x-1203-y1 1200 1200 4510 420 4510 600
DCS50x-1503-y1 1500 1500 4740 460 4740 640 5540 850 5540 1080
DCS50x-2003-y1 2000 2000 5950 470 5950 660 6820 1100 6820 1370
DCS50x-1903-81 1900 1900 7150 1800
DCS50x-2053-y1 2050 2050 7160 880 8050 1140 8050 1410 7300 1820
DCS501-2503-y1 2500 8250 590 8250 800 8930 1220 8930 1510 8930 1830
DCS502-2503-y1 2500 8400 900 7820 1200 8400 1510 8400 1850 8400 2210
DCS501-3003-y1 3000 9570 450 9750 620 9430 1410 9430 1740 9430 2090
DCS502-3003-y1 3000 9900 900 9900 1200 10300 1510 10300 1850 10300 2210
DCS50x-2053-91 2050 2050 7090 2630
DCS50x-2603-91 2600 2600 9420 2690
DCS50x-3303-y1 3300 3300 10850 570 10850 780 11700 1190 11700 1470 11700 1780 11600 4650
DCS50x-4003-y1 4000 4000 12300 480 12300 660 13350 1520 13350 1860 13350 2230 15400 4800
DCS50x-4803-y1 4800 4800 16800 2300 16800 2750 16800 3250
DCS50x-5203-y1 5200 5200 17250 1390 17250 1800
Table 2.4/1: DCS 500 Power losses
III 2-14
3ADW000165R0201_Technical_Data_e_b
2.5 Power section cooling
Fan assignment for DCS 500
Fan data for DCS 500
Fan connection for DCS 500
Table 2.5/2: Fan data for DCS 500
Table 2.5/1: Fan assignment for DCS 500
III 2-15
3ADW000165R0201_Technical_Data_e_b
Monitoring the DCS 500 power section
it is here not mounted on a heat sink but close to
the fan air outlet. The detector thus measures the
power section’s radiated heat and any changes
in the cooling air temperature and volume. Since
the cooling air volume can only be detected
indirectly, a differential-pressure switch has been
additionally fitted at the unit’s housing, always
located close to the power terminals.
The resistance change proportional to the
temperature is acquired and evaluated in the
unit’s software. If the temperature rises above the
parameterized value, then first an alarm will be
outputted, and - if the temperature continues to
ris
主营产品简介
专注于DCS、PLC、机器人控制系统、大型伺服四大系统领域。
主营产品各种模块/卡件,控制器,触摸屏,伺服驱动器。
优势:供应进口原装正品,专业停产配件,
发货快,货期精准,
主营品牌包括 ABB贝利、GE/FUANC、FOXBORO、英维思TRICONEX 、本特利BENTLY、A-B罗克韦尔、艾默生EMERSON 、OVATION、MOTOROLA、XYVOM、霍尼韦尔HONEYWELL 、力士乐REXROTH、KUKA、NI、DEIF、横河、伍德沃德WOODWARD、瑞恩、施耐德SCHNEIDER 、安川、 穆格MOOG、PROSOFT等品牌
Copyright ©2019-2022 瑞昌明盛自动化设备有限公司 版权所有 赣ICP备2021006016号